Sec. 4-7.07. Alluvial Fan Advisory.
   (a)   Hazards of Alluvial Fan Development. Alluvial fans present a unique flood hazard environment where the combination of sediment, slope, and topography create an ultra hazardous condition for which elevation on fill will not provide reliable protection. Active alluvial fan flooding is characterized by flow path uncertainty combined with abrupt deposition and erosion. As a result, any area of an alluvial fan may be subject to intense flood hazards.
   The technology of mathematically modeling the hydrodynamics of water and debris flows for alluvial fans is still in the early development stage. The Federal Emergency Management Agency (FEMA) has formulated a mapping procedure for the purpose of defining the likelihood of flood hazards on inundated alluvial fan zones to be used for flood insurance purposes and general floodplain regulation, referred to as the FEMA alluvial fan methodology.
   An active alluvial fan flooding hazard is indicated by three related criteria:
   (1)   Flow path uncertainty below the hydrographic apex;
   (2)   Abrupt deposition and ensuing erosion of sediment as a stream or debris flow loses its competence to carry material eroded from a steeper, upstream source area; and
   (3)   An environment where the combination of sediment availability, slope, and topography creates an ultra hazardous condition for which elevation on fill will not reliably mitigate the risk.
   Inactive alluvial fan flooding is similar to traditional riverine flood hazards, but occurs only on alluvial fans. It is characterized by flow paths with a higher degree of certainty in realistic assessments of flood risk or in the reliable mitigation of the hazard. Counter to active alluvial fan flooding hazards, an inactive alluvial fan flooding hazard is characterized by relatively stable flow paths. However, areas of inactive alluvial fan flooding, as with active alluvial fan flooding, may be subject to sediment deposition and erosion, but to a degree that does not cause flow path instability and uncertainty.
   An alluvial fan may exhibit both active alluvial fan flooding and inactive alluvial fan flooding hazards. The hazards may vary spatially or vary at the same location, contingent on the level of flow discharge. Spatially, for example, upstream inactive portions of the alluvial fan may distribute flood flow to active areas at the distal part of the alluvial fan. Hazards may vary at the same location, for example, with a flow path that may be stable for lower flows, but become unstable at higher flows.
   More detailed information can be found at FEMA's website: "Guidelines for Determining Flood Hazards on Alluvial Fans" at http://www.fema.gov/fhm/ft_afgd2.shtm#1.
   (b)   Alluvial Fans and LOMR's. The NFIP does not allow for the removal of land from the floodplain based on the placement of fill (LOMR-F) in alluvial fan flood hazard areas. The NFIP will credit a major structural flood control project, through the LOMR process, that will effectively eliminate alluvial fan flood hazards from the protected area. Details about map revisions for alluvial fan areas can be found in the Code of Federal Regulations at Title 44, Part 65.13.
   (c)   Alluvial Fan Task Force. As stated in AB 2141 (Longville, Chapter 878, Statutes of 2004), the State of California Department of Water Resources will convene an Alluvial Fan Task Force (AFTF). The AFTF will produce an alluvial fan model ordinance for local communities and a recommendations report to the legislature.
(§ 2, Ord. 1531-NS, eff. February 11, 2010)
Editor’s Note:
   Former Sec. 4-707 Warnings and disclaimers of liability has been repealed and replaced by Ord. 1531-NS § 1, effective February 11, 2010. (§ 1, Ord. 696-NS, eff. November 16, 1978; repealed by § I Ord, 994-NS, eff April 12, 1988)