Sec. 8-7.09. Amendments: Appendix AZ - Emergency Housing.
   Section AZ103.3 “Occupant Load” is amended to read as follows:
   AZ103.3 Occupant Load.
   Except as otherwise stated in this appendix, the maximum occupant load allowed in buildings and structures used as emergency housing shall be determined by the enforcing agency, but the interior floor area shall not be less than 64 square feet (5.9 m2) for one occupant. Where more than one person occupies the building/structure, the required floor area shall be increased at the rate of 50 square feet (4.65 m2) for each occupant in excess of one.
   Exceptions:
   1.   Tents.
   2.   Recreational vehicles and park trailers designed for human habitation that meet the requirements in the Health and Safety Code, Sections 18009.3 and 18010, as applicable.
   3.   For emergency housing, including emergency sleeping cabins, the minimum interior floor area may be reduced to 53 square feet (4.9 m2) if the enforcing agency determines that 53 square feet (4.9 m2) is adequate space for a single-occupancy sleeping unit.
   Section AZ104.1 “General” is amended to read as follows:
   AZ104.1 General.
   Emergency sleeping cabins shall have an interior floor area of not less than 64 square feet (5.9 m2) for one occupant. Where more than one person occupies the cabin, the required floor area shall be increased at the rate of 50 square feet (4.65 m2) for each occupant in excess of one. The interior floor area shall not exceed 400 square feet (37 m2), excluding lofts.
(§ 6, Ord. 1707-NS, eff. January 1, 2023)