(a) A minimum of two exits shall be provided where a portable structure and or tent is used as a place of public assembly with a capacity of 100 or more persons, and if the capacity exceeds 600, there shall be not less than four exits.
(b) The aggregate clear width of exit openings shall be determined on the basis of not less than one unit of 22 inches for each 100 persons accommodated. Exit openings as required shall not be less than 42 inches in clear width, nor less in width than the required width of aisles or passageways serving such exit openings as contained in Section 1345.10, and where capacities exceed 600 persons, exit openings as required shall not be less than five feet in clear width.
(c) The line of exit travel to exits shall not be greater than 100 feet.