(a) Street Grade Approval. No street grading shall be permitted until the Phase I Plan has been approved by the Planning Board and the City Engineer has approved the final construction drawings. The entire width of the right-of-way shall be brought to the approved grade and sloped at an angle agreeable to the Director, back from the property line to meet existing or planned elevation.
(b) Specifications. The design and construction of curb and gutter, streets, walks, drainage facilities, sanitary facilities, and water lines shall be in accordance with the rules, regulations, and specifications of the City.
(c) Fence. When required as specified in Section 1211.01
(l), fences shall be of the chain-link type or other acceptable all metal material design and three-and-one-half (3-1/2) feet or more in height.
(d) Permanent Monuments. Permanent monuments shall be made of stone or concrete, thirty-six (36) inches in length and six (6) inches in diameter, or six (6) inches square with a reinforcing bar or pipe cast in the center.
(e) Street Lights.
(1) All street lights constructed in new subdivisions shall be constructed in conformity to specifications and ordinances of the City and the specifications of the public utility which shall be providing power to such street lights. After street lights have been constructed in a new subdivision, the developer shall provide written verification to the City from the public utility providing power to the street lights certifying that the subdivider and the subdivider’s developer has satisfactorily complied with the specifications of the public utility and the public utility will provide power to illuminate the street lights.
(2) All street lighting shall be a type and style mutually approved by the City and the public utility company which shall provide power to illuminate the street lights.
(Ord. 23-159. Passed 5-23-23.)
(3) Roadways shall be lighted to the following minimum levels, based on the classification of the roadway.
Minor | 0.35 maintained foot-candles |
Collector | 0.60 maintained foot-candles |
Major and Secondary | 1.00 maintained foot-candles |
(4) The underground power cable and all switching controls for the lighting system shall be designed and installed per standards established by the public utility furnishing electrical power and in conformance with municipal ordinances.
(5) All lighting units shall be a type mutually approved by the City and the public utility which shall provide power to illuminate the lighting units, and painted black. This luminaire shall meet all requirements as specified by the public utility which shall provide power to illuminate the luminaire.
(6) All supports shall be of a type mutually approved by the City and the utility which shall provide power to illuminate the lighting units and painted black. All supports shall meet the requirements as specified by the pubic utility which shall provide power to illuminate the completed lighting system.
(7) Lighting units shall be mounted at a sufficient height to prevent veiling glare. Proper heights shall be determined through the public utility which shall provide power to illuminate the completed lighting system and the manufacturer of the luminaire.
(8) The lighting plan submitted for approval shall include a scaled drawing of the development showing the location of all proposed lighting units and associated wiring. Additionally, calculations shall be furnished to show the lighting level(s) furnished by the proposed layout.
(9) The lighting plan shall be approved by the public utility providing power to illuminate the completed lighting system and the City before installation may be commenced. Service Department shall be contacted a minimum of 72 hours prior to installation.
(Ord. 23-159. Passed 5-23-23.)