Skip to code content (skip section selection)
Compare to:
Signal Hill Overview
Signal Hill Municipal Code
SIGNAL HILL, CALIFORNIA MUNICIPAL CODE
PREFACE
Title 1 GENERAL PROVISIONS
Title 2 ADMINISTRATION AND PERSONNEL
Title 3 REVENUE AND FINANCE
Title 4 (Reserved)
Title 5 BUSINESS TAXES, LICENSES AND REGULATIONS
Title 6 ANIMALS
Title 7 (Reserved)
Title 8 HEALTH AND SAFETY
Title 9 PUBLIC PEACE, MORALS AND WELFARE
Title 10 VEHICLES AND TRAFFIC
Title 11 (Reserved)
Title 12 STREETS, SIDEWALKS AND PUBLIC PLACES
Title 13 PUBLIC UTILITIES
Title 14 (Reserved)
Title 15 BUILDINGS AND CONSTRUCTION
Title 16 OIL AND GAS CODE*
Title 17 TRAILER PARKS
Title 18 SUBDIVISIONS*
Title 19 (Reserved)
Title 20 ZONING
Title 21 PUBLIC DEDICATION REQUIREMENTS AND IMPROVEMENT FEES TO BE PAID BY DEVELOPMENT PROJECTS
STATUTORY REFERENCES FOR CALIFORNIA CITIES
PRIOR CODE CROSS-REFERENCE TABLE
ORDINANCE LIST AND DISPOSITION TABLE
Chapter 17.16
DESIGN, CONSTRUCTION, AND MAINTENANCE
Sections:
   17.16.010   Office required--Maintenance of approved plot plan.
   17.16.020   Caretaker required--Enforcement.
   17.16.030   Park maintenance responsibility.
   17.16.040   Site drainage--Density--Lot size and frontage.
   17.16.050   Trailer location.
   17.16.060   Location of structures on site.
   17.16.070   Occupied area.
   17.16.080   Construction and maintenance of structures.
   17.16.090   Streets and driveways.
   17.16.100   Curbs, gutters, sidewalks.
   17.16.110   Paving, surfacing, and planting of grass.
   17.16.120   Obstructions prohibited--Storage cabinet placement.
   17.16.130   Boundary marking.
   17.16.140   Masonry walls--Required locations.
   17.16.150   Masonry walls--Construction specifications.
   17.16.160   Awnings.
   17.16.170   Windbreaks.
   17.16.180   Sewage disposal and toilet and bath facilities.
   17.16.190   Laundry facilities.
   17.16.200   Window screens for toilets and laundries.
   17.16.210   Plumbing.
   17.16.220   Wastewater disposal.
   17.16.230   LPG storage vessels.
   17.16.240   Gas-burning appliances.
   17.16.250   Electrical standards.
   17.16.260   Electrical grounding.
   17.16.270   Electrical installations--Workmanlike methods.
   17.16.280   Trailer coach connections--Responsibility.
   17.16.290   Illumination at night.
   17.16.300   Garbage receptacles and disposal.
   17.16.310   Park sanitation.
   17.16.320   Animals.
   17.16.330   Fire protection.
17.16.010   Office required--Maintenance of approved plot plan.
   Each trailer park shall have at all times an office in a permanent building. The owner or operator of every trailer park shall maintain in a conspicuous location in the office a copy of an approved plot of the trailer park. The plot plan shall show in detail the site layout and the location of trailers, and each site shall be designated by number or by other means of identification.
(Prior code § 17.16.020 (Ord. 503 § 5.0, 1961))
17.16.020   Caretaker required--Enforcement.
   It is unlawful for any person to operate or maintain, or cause or permit to be operated or maintained, any trailer park unless there is a caretaker in the park at all times. The caretaker shall enforce within the park provisions of this title governing the operation and maintenance of trailer parks.
(Prior code § 17.16.010(A) (Ord. 503 § 4.5(a), 1961))
17.16.030   Park maintenance responsibility.
   A.   All devices or safeguards required in trailer parks by this title shall be maintained in good working order. The owner, operator, or lessee of the trailer park, or his designated agent, shall be responsible for their maintenance.
   B.   The owner or operator of a trailer park shall be responsible for the maintenance of all structures and their sites in an approved, safe, and sanitary condition and in a state of good repair.
(Prior code § 17.16.140(A, B) (Ord. 503 § 10.5(a), (b), 1961))
17.16.040   Site drainage--Density--Lot size and frontage.
   A.   Trailer parks shall be developed on well-drained sites, properly graded to provide for adequate drainage and freedom from standing pools of water. Such sites shall be free from street overflow as determined by engineering design.
   B.   No trailer park shall contain an overall density of more than eighteen trailer sites per acre.
   C.   Each trailer site shall have an area of at least one thousand eight hundred square feet with a minimum frontage width of thirty-five feet facing on a roadway. Any trailer site, such as a cul-de-sac lot, unable to meet the minimum frontage requirement, but having the one thousand eight hundred square foot area may have less than the minimum frontage if the building inspector determines the conditions to justify it. The frontage of cul-de-sac lots shall be measured at the building setback line.
(Prior code § 17.16.030 (Ord. 503 § 5.5, 1961))
17.16.050   Trailer location.
   A.   No trailer coach shall be located within a trailer park so that it is nearer than ten feet from any building or another trailer coach; provided, however, that this does not apply to a compartment containing solely a private toilet or bath, or both, constructed for the exclusive use of an occupant of a trailer site designed for the occupancy of one trailer coach.
   B.   No trailer coach and no building or structure shall be located within a trailer park nearer than five feet from the side and rear property lines or side and rear trailer site lot lines; provided, however, that where trailers are parked rear-to-rear, the minimum rear setback shall be four feet.
(Prior code § 17.16.070 (Ord. 503 § 7.0, 1961))
17.16.060   Location of structures on site.
   A.   No structure in a trailer park or any portion or projection thereof shall be located within four feet of the trailer park boundary or the trailer site lot line.
   B.   No structure in a trailer park or any portion or projection thereof, including an approved awning, shall be located nearer than ten feet from any trailer coach or awning on an adjacent trailer site; provided, however, that a windbreak may be located on the lot line if it is at least five feet from any trailer or awning.
   C.   To prevent obstruction of natural light and ventilation no awning, building, windbreak, or combination thereof, shall be erected, placed, or maintained on more than one side or one end of any trailer coach in a trailer park.
(Prior code § 17.16.120 (Ord. 503 § 9.5, 1961))