1315.06 OUTRIGGER SCAFFOLDS.
   During the wrecking of any building, and where required by the Building Official, outrigger scaffolds shall be constructed on all sides of the building which are within ten feet of a traveled thoroughfare and on all sides that are adjacent to and extend above any occupied building lot. These outrigger scaffolds shall be located not more than two stories below the point where any wrecking or handling of outside wall material is being done. The floor or platform of all such outrigger scaffolds shall be tightly laid from the edge of the building and shall be at least eight feet wide with a thirty-inch solid railing or foot board at the outside edge. The flooring and its supports or outriggers shall be capable of sustaining a live load of not less than 125 psf, and in no case shall any material less than the nominal two inch in thickness be used in their construction. (Ord. 61-20. Passed 5-16-61; Ord. 2015-36. Passed 9-8-15.)