The building standards contained in the California Building Code, Chapter 7A, shall apply in the Foothill Fire Zones and in state designated Very High Fire Hazard Severity Zones. In addition, the following requirements shall apply as noted herein:
A. Fencing shall be of approved noncombustible or ignition-resistant material.
B. Vinyl window frame assemblies shall have the following characteristics:
1. Frames shall have welded corners and metal reinforcement in the interlock area;
2. Dual-paned insulated glazed units with at least one pane of tempered glass;
3. Frame and sash profiles are certified in AAMA Lineal Certification Program (verified by an AAMA product label or a Certified Products Directory);
4. Certified and labeled to ANSI/AAMA/NWWDA 101/I.S.2-97 for structural requirements.
C. Roof mounted turbine vents shall not be permitted
D. All roof coverings shall be of non-wood materials with at least a Class A fire-retardant rating.