15.20.030   Local amendments to the CBC.
   A.   Subsection 502.1.1 is added to the end of the CBC section 502.1 to read as follows:
      502.1.1 Address Illumination. Addressing shall be illuminated at night in all new buildings. Address signs shall be internally or externally illuminated. When the luminance or the face of a sign is from an external source, it shall have an intensity of not less than 5.0 foot-candles. Internally illuminated signs shall provide equivalent luminance.
   B.   CBC section 1208.4 is amended to read as follows:
      1208.4 Efficiency dwelling units. Efficiency dwelling units shall comply with the following:
      1.   The unit shall be occupied by no more than two persons and have a living room of not less than 150 square feet (13.9 m²) of floor area.
      2.   The unit shall be provided with a separate closet.
      3.   For other than Accessible, adaptable dwelling units, the unit shall be provided with a kitchen sink, cooking appliance and refrigerator, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided.
      4.   The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower.
   C.   CBC Appendix C section 104.1 is amended to read as follows:
C104.1 Exit facilities: Exits shall be provided in accordance with Chapter 10 and Chapter 11A or 11B as applicable.
(Ord. 2022-0026 § 8; Ord. 2019-0042 § 9; Ord. 2017-0042 § 5; Ord. 2014-0001 § 8)