§ 53.017 LOCAL LIMITS.
   (A)   An industrial waste survey is required prior to a user discharging wastewater containing in excess of the following average discharge limits.
BOD
300 mg/1
TSS
300 mg/1
Total nitrogen
50 mg/1
NH3
25 mg/1
Arsenic
0.003 mg/1
Cadmium
0.0015 mg/1
Chromium
0.05 mg/1 (total chromium)
Copper
0.061 mg/l
Cyanide
0.015 mg/1
Lead
0.003 mg/l
Mercury
0.0003 mg/1
Nickel
0.021 mg/1
Silver
0.005 mg/1
Zinc
0.175 mg/1
 
   (B)   Industrial waste survey information will be used to develop user-specific local limits when necessary to ensure that the POTW’s maximum allowable headworks loadings are not exceeded for particular pollutants of concern. User-specific local limits for appropriate pollutants of concern shall be included in wastewater permits. The POTW Director may impose mass-based limits in addition to, or in place of concentration-based limits.
(Ord. passed 2-12-2013)