§ 160.012 EXEMPTIONS FROM SITE RUNOFF STORAGE REQUIREMENTS (DETENTION).
   Site run-off storage is not required under the following circumstances:
   (A)   Direct discharge industrial sites.
   (B)   Non-industrial direct discharge sites 160 acres or less having the following minimum river frontage:
 
Site Area
Required Frontage
0 to 2 acres
50 ft.
up to 5 acres
100 ft.
up to 10 acres
150 ft.
up to 40 acres
200 ft.
up to 80 acres
350 ft.
up to 160 acres
500 ft.
 