§ 151.21 TABLES OF REGULATIONS.
   (A)   Road width for parking.
 
Table A
Road Width for Parking
Road Width
Parking
24 feet
No parking on streets; two-way traffic
30 feet
Parking one side of street
36 feet
Parking two sides of street
 
   (B)   Distribution system piping.
 
Table B
Distribution System Piping
Side of Main (inside diameter)
Number of MH that May Be Serviced
Max Length of Main Installed (feet)
2 inches
20
600
3 inches
60
1,800
4 inches
120
3,600
6 inches
400
12,000
Notes to Table:
If local requirements exceed the above sizes, the local standards will apply.
 
   (C)   Minimum size and slope of sewer mains.
 
Table C
Minimum Size and Slope of Sewer Mains*
Number of Spaces
Sewer Inside Diameter (inches)
Minimum Slope (per foot)
1-125
6
1/8 inches
More than 125
8
1/8 inches
Notes to Table:
* = Exclusive of laterals serving individual mobile homes
 
   (D)   Demand factors for feeder and service entrance conductors.
Table D
Demand Factors for Feeder and Service Entrance Conductors
Number of Mobile Homes
Demand Factor (percent)
Table D
Demand Factors for Feeder and Service Entrance Conductors
Number of Mobile Homes
Demand Factor (percent)
7-9
28
10-12
27
13-15
26
16-21
25
22-40
24
41-60
23
61 and over
22
Notes to Table:
The demand factor for a given number of lots shall apply to all lots indicated.
Example: Twenty lots calculated at 25% of 16,000 watts results in a permissible demand of 4,000 watts per lot or a total of 80,000 watts for 20 lots.
 
(Prior Code, § 3-4-10) (Res. passed 5-20-1986)