155.3213. MOBILE HOME PARK (MH-12)
A. Purpose
Typical Building Type
A. Purpose
Typical Building Type
The Mobile Home Park (MH-12) district is established and intended to accommodate mobile home parks that primarily function to provide spaces for individual mobile homes intended to be occupied as permanent living quarters. The district also accommodates recreational facilities and other accessory uses serving occupants of the mobile home park.
B. Use Standards
See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. Intensity and Dimensional Standards for Mobile Home Parks with Public Internal Roadways 1
Lot area, minimum (acres)
5
Typical Lot Pattern
Lot width, minimum (ft)
300
Density, maximum (du/ac)
12 2
Height, maximum (ft)
12
Setback from a waterway or canal, minimum (ft)
25
Front yard setback per mobile home space from public internal roadway, minimum (ft)
6
Front yard setback per mobile home space from public external roadway, minimum (ft)
25
Street side setback per mobile home space from public internal roadway, minimum (ft)
6
Street side yard setback per mobile home space from public external roadway, minimum (ft)
25
Interior side yard setback per mobile home space, minimum (ft)
10 3
Rear yard setback per mobile home space, minimum (ft)
15 3
Spacing between mobile homes, minimum (ft)
10 3
Dimensional Standards for Accessory Structures
See Accessory Use-Specific standards in Article 4: Part 3. However there shall be a minimum of 25 ft between a mobile home and any accessory structure or service structure used in conjunction with the park.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]

1. See measurement rules and allowed exceptions/variations in Article 9:Part 4.

2. On
land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land use classification.

3. If the mobile home park was zoned R-1T under former
county zoning and consists of mobile home spaces that are individually owned or leased for terms of one year or more, the minimum front and street side yard setbacks are 6 ft, the interior side yard setback is 4 ft, the rear yard setback is 8 ft, and the interior side yard setback for roofed carports is 2 ft.
D. Intensity and Dimensional Standards for Mobile Home Parks with Private Internal Roadways 1
Lot area, minimum (acres)
5
Lot width, minimum (ft) 300
300
Density, maximum (du/ac)
122
Height, maximum (ft)
12
Setback from a waterway or canal, minimum (ft)
25
Front yard setback per mobile home space from public roadway, minimum (ft)
25
Front yard setback per mobile home space from private roadway, minimum (ft)
15
Street side yard setback per mobile home space from public or private roadway, minimum (ft)
25
Interior side yard setback per mobile home space from public or private roadway, minimum (ft)
10
Rear yard setback permobile home space from public or private roadway, minimum (ft)
15
Spacing between mobile homes, minimum (ft)
10
Dimensional Standards for Accessory Structures
See Accessory Use-Specific standards in Article 4: Part 3. However there shall be a minimum of 25 ft between a mobile home and any accessory structure or service structure used in conjunction with the park.
NOTES:
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4.
2. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land use classification.
Typical Development Configuration
 
 
(Ord. 2012-64, passed 9-11-12; Am. Ord. 2013-37, passed 1-22-13; Am. Ord. 2014-16, passed 1-28-14)