§ 51.106 COMPUTATION OF SURCHARGE.
   (A)   The surcharge per person shall be computed by the following formula:
   S = V (0.00834 x .748) [(A (BOD5 - 200) + B (SS - 240)] + C (V - 1,500)
   Where:
   S = Amount of Surcharge ($)
   V = Wastewater Volume in units of 100 cubic feet
   (0.00834 x .748) = Unit weight of water x 10-6 per hundred cubic feet
   A = Unit charge for BOD5 per lb. (§ 51.090)
   BOD5 = Five day biochemical oxygen demand, mg/l
200 = Allowable BOD
5 strength
   B = Unit of charges for SS per pound. (§ 51.090)
   240 = Allowable SS, mg/l
   C = Unit charge for Volume in dollars per 100 cubic feet (§ 51.090)
   1,500 = Allowed Wastewater Volume in HCF per billing period
   (B)   The concentration of wastes used for computing surcharges shall be established by waste sampling. Waste sampling shall be performed as often as may be deemed necessary by the Operator and shall be binding as a basis for surcharge.
('72 Code, § 51.066) (Ord. 51-A, passed 10-4-76; Am. Ord. 19-03, passed 5-6-19)