(A) Placement of monuments. Monuments, consisting of one-half-inch iron pipe or one-half-inch reinforced steel or larger, 24 inches in length (if deep sand, three-quarter-rods and 36 inches long), shall be placed at all corners of the block lines, and at the point of intersection of curves and tangents of the subdivision.
(B) Bench mark. At least one bench mark for each subdivision shall be permanently installed in an approved manner, with the location and the elevation as shown on the plat. Permanent bench marks shall be five feet long concrete posts six inches in diameter with the top to be at least 12 inches below finished grade.
(C) Lot marker. Lot markers shall be one-half-inch rebars, at least 24 inches in length, placed at each corner of all lots, flush with the average ground elevation, or they may be countersunk if necessary to avoid being disturbed.
(Ord. 1252, passed 1-22-2004)