(A) The applicant for any permit required for work involving outdoor lighting for commercial, office, industrial, and institutional projects with a gross floor area of more than 3,000 square feet, residential projects other than single-family dwellings of more than five units, all vehicular canopies and all outdoor display areas shall submit documentation at time of site plan or plot plan approval that the proposed lighting plan complies with the provisions of this lighting standard.
(B) The submission shall contain, but not be limited to, the following, all or part of which may be part of or in addition to the information required elsewhere in these lighting standards.
(1) (a) A lighting plan to scale is required that shows a point-by-point footcandle array on a ten feet by ten feet grid in a printout format indicating the location and aiming of illuminating devices.
(b) The printout shall indicate compliance with the maximum average maintained footcandles, light trespass, and uniformity required by this lighting standard.
(2) Description of the fixture types, lamps, poles, mounting height, raised foundations, and the IESNA cutoff classification for the fixture and other devices (including, but not limited to, manufacturers or electric utility catalog specification sheets and/or drawings).
(3) (a) The above required plans and descriptions shall be sufficiently complete to enable the Administrator to readily determine compliance with the requirements of this chapter.
(b) Projects that are not required to submit items identified in this section are still subject to comply with the provisions of these lighting standards and may be required to provide this information upon request by the town at a later date.
(2003 Code, § 28.13)