(A) This subchapter applies only to new construction of a Class 1 structure and a Class 2 structure.
(B) (1) As used in this subchapter, ENGINEERED LUMBER ROOF TRUSSES AND/OR FLOOR JOISTS refers to a structural assembly that:
(a) Is fabricated from:
1. Wood;
2. Light gauge metal;
3. Other component materials; or
4. Any combination of materials described in divisions (B)(1)(a)1. through (B)(1)(a)3. above.
(b) Has less mass cross sectional area than sawn lumber members that would be used in an equivalent application;
(c) Is assembled from combustible or noncombustible materials, or both; and
(d) Is not a vertical member and supports a roof or floor, or both.
(2) The term does not include a structural assembly that provides a minimum of one hour fire resistance when tested in accordance with ASTM Standard E119.
(3) As used in this subchapter, OWNER means a person having control or custody of any structure to which this subchapter applies.
(C) (1) A structure that contains engineered lumber roof trusses and/or floor joists must have a placard affixed to the structure that meets the requirements of this subchapter.
(2) The placard shall use yellow reflective coding and lettering that identifies both of the following:
(a) The types of engineered lumber roof trusses and floor joists used in the structure, including truss or engineered lumber; and
(b) The location of engineered lumber roof trusses and/or floor joists used in the structure including floor joists or truss roof systems.
(3) The placard may not be:
(a) Smaller than three and one-half inches by four and one-half inches; and
(b) Larger than five inches by five and one-half inches.
(D) The placard must be permanently affixed:
(1) Below the structure’s electrical meter, if the structure has electrical service; or
(2) On the left side of the front entrance four to six feet above the ground, if the structure does not have electrical service.
(E) (1) An applicant for a building permit must indicate on the application:
(a) The types of engineered lumber roof trusses and/or floor joists used in the structure; and
(b) The location of the engineered lumber roof trusses and/or floor joists used in the structure.
(2) The application form for a building permit must include a place on the form for providing the information under division (E)(1) above.
(3) An applicant for a building permit shall not be issued a building permit unless the individual at the time of the application is issued:
(a) A placard by the Building Commissioner; and
(b) A fee, not to exceed $5, may be charged for each placard issued.
(F) Unless a placard is affixed to the structure that meets the requirements of this subchapter, the Building Commissioner shall not:
(1) Approve a structure on final inspection; or
(2) Issue a certificate of occupancy for a structure.
(G) (1) Not later than ten business days after issuing a building permit, the Building Commissioner shall send written notification to the local fire department and the 911 telephone call center that has jurisdiction in the area where the structure is located. The notification shall be sent by certified mail, return receipt requested.
(2) The notification must include the following information:
(a) The street address of the property;
(b) The name of the municipality and county in which the structure is located;
(c) The types of engineered lumber roof trusses and/or floor joists used in the structure; and
(d) The location of the engineered lumber roof trusses and/or floor joists by area within the structure.
(H) Upon receiving a copy of the notification under division (G) above, the Chief of the Fire Department or the Chief’s designee shall:
(1) Post the information in a conspicuous place for all emergency personnel;
(2) Provide the information to any fire department providing mutual aid; and
(3) For Class 1 structures only, add the structure to the inspection file for follow up on a timely basis for inspection.
(I) Upon receiving a notification under division (G) above, the 911 telephone call center shall maintain the information on each property, by the address of the property, that uses engineered lumber roof trusses and/or floor joists. When dispatching to the listed address, the dispatcher shall notify the responding units of the information.
(J) An owner of a structure shall ensure that the placard remains affixed to the structure during the life of the structure.
(BC Ord. passed 8-19-2013) Penalty, see § 151.999