(a) Sanitary sewer improvements shall be installed by the subdivider in conformance with the Public Works Standards.
(b) Sanitary sewers shall have a minimum diameter of eight (8) inches.
(c) Lateral connections shall be provided for each lot or for each primary building on the lot from the sanitary sewer to a point three feet past the inside curb line as approved by the Director.
(d) Sanitary sewage shall not be drained into storm sewers. Storm water, including yard drainage tile, footer drains and roof drainage tile, shall not be drained into a sanitary sewer.
(e) Grades of sanitary sewers shall be designed and installed to provide a minimum flow velocity of two feet per second when the pipe is full.
(f) Sewage lift stations, sewage grinder pumps, or individual household sewage disposal systems shall only be permitted under circumstances of extreme hardship with the approval of the Director and the Planning Commission.
(g) The Director may require that the subdivider install water mains larger than the adequate design required for the water demands of the subdivision itself, however, any such requirement and agreement to pay for such additional requirement with municipal funds shall only be made with approval of City Council.
(Ord. 96-82 AC. Passed 9-16-96.)