§ 152.244 NOISE STANDARDS IN THE I-1 LIGHT INDUSTRIAL DISTRICT AND PD-4 INDUSTRIAL PLANNED DEVELOPMENT DISTRICT.
   In the I-1 Light Industrial district and the PD-4 Industrial Planned Development District, at no point on or beyond the boundary of the zoning district shall the sound pressure level resulting from any use, operation, or activity exceed the maximum permitted sound levels as set forth in Tables IC and IIC:
TABLE IC: PREFERRED FREQUENCIES
Center Frequency, Cycles Per Second
Maximum Permitted Sound Pressure Level, Decibels
TABLE IC: PREFERRED FREQUENCIES
Center Frequency, Cycles Per Second
Maximum Permitted Sound Pressure Level, Decibels
      31.5
76
      63.0
74
      125.0
68
      250.0
63
      500.0
57
      1,000.0
52
      2,000.0
45
      4,000.0
38
      8,000.0
32
TABLE IIC: PRE-1960 OCTAVE BANDS
Octave Band, Cycles Per Second
Maximum Permitted Sound Pressure Level, Decibels
TABLE IIC: PRE-1960 OCTAVE BANDS
Octave Band, Cycles Per Second
Maximum Permitted Sound Pressure Level, Decibels
      20 -   75
75
      75 -   150
70
      150 -   300
64
      300 -   600
59
      600 -   1200
53
      1200 -   2400
47
      2400 -   4800
40
      4800 -   10 KC
34
 
('80 Code, § 152.244) (Ord. 94-14, passed 7-5-94)