Table 153.023 - Standards for New or Expanded Development | ||||
Standards by Zoning District | Residential (R-1, R-2 & R-3) | Commercial- Residential (CR) | Industrial (LI) & (HI) | Public Fac. (PF) Open Space (OS) Water (W) |
Table 153.023 - Standards for New or Expanded Development | ||||
Standards by Zoning District | Residential (R-1, R-2 & R-3) | Commercial- Residential (CR) | Industrial (LI) & (HI) | Public Fac. (PF) Open Space (OS) Water (W) |
Maximum lot coverage; total area covered by structures and impervious paved surfaces, including decks and accessory structures | 60% | 80%, except 90% for lots fronting Spruce Street | 80% | PF: 70% |
OS: 20% | ||||
W: 0% | ||||
Maximum structure height | 35 ft, subject to the following standards: | |||
The city may limit height as required for fire protection. | ||||
The height of a new dwelling shall not exceed the height of an existing dwelling on an abutting lot by more than one foot for every one foot of combined side or rear yard setback, as applicable, separating the two dwellings. | ||||
Notwithstanding the provisions of this table, an increased height is allowed in any zone, subject to approval of a conditional use permit and provided fire protection requirements met. | ||||
Minimum lot area (square feet), except existing lots of record smaller than standard may be developed pursuant to § 153.003 | 6,000 sq. ft.; except 7,500 sq. ft. for two- family (duplex) dwelling, and 3,750 sq. ft. for attached single-family (townhome) dwelling | 5,000 sq. ft.; except 7,500 sq. ft. for two- family (duplex) dwelling, and 3,750 sq. ft. for attached single-family (townhome) dwelling | None: Building code standards must be met. | |
For multi-family use, 7,500 sq. ft., plus an additional 1,000 sq. ft. for each dwelling unit over two on a lot. | For multi-family use, 7,500 sq. ft., plus an additional 1,000 sq. ft. for each dwelling unit over two on a lot. | |||
Minimum lot width at front building line | None: Building code standards must be met. | Not applicable | ||
Common wall/zero lot line development | 30 ft | 30 ft | ||
Minimum lot depth | 65 ft | 65 ft | ||
Non-common wall development | 50 ft | 50 ft | ||
Minimum common open space area in new residential subdivisions and multi-family developments, as of a % of the overall site. Applies to all land use applications submitted after February 3, 2012 | 20% | 10% | Not applicable | |
Minimum front or street side setback on lot abutting standard right-of-way | 15 ft. in R-1, R-2, R-3, PF and OS Zones and 0 ft. in CR, LI and HI Zones; except 20 ft. for the following: garage openings; carport entries; structures where vehicles are serviced, stored or repaired; structures associated with vehicle queuing areas (e.g., kiosks, drive-up/drive-through facilities, ATMs and the like) and similar structures. | |||
Notwithstanding the above, developments adjacent to Spruce Street shall be setback not more than 5 ft., except the setback may be increased where a plaza is proposed between a building and the property line. Developments adjacent to Hwy 42 shall conform to the highway corridor/gateway landscape standards in §§ 153.155 through 153.159, which may require a setback yard for landscaping. | ||||
See also § 153.023(B). | ||||
Minimum front or street side setback on lot abutting sub-standard right-of-way | Where an existing street right-of-way is less than the standard width provided in §§ 153.185 through 153.194, the minimum front or street setback equals one-half of the ultimate/planned width of the abutting right-of-way, per the city’s transportation system plan, as measured from the street or highway centerline, as applicable. | |||
Minimum interior side setback | 5 ft., except where common wall/zero-lot line development is approved with 0 ft. setback, or where greater setback is required per CU permit. | Three ft., except where common wall/zero lot line development is approved with 0 ft. setback, or where greater setback is required per CU permit. | ||
Minimum rear setback | 15 ft., except a setback of 5 ft. is permitted for accessory structures of 12 ft. or less in height | 3 ft., except as required by utility easement or building code | ||
(B) Setback yard exceptions. Setback yards provide space for private yards and building separation for fire protection/security, building maintenance, sunlight and air circulation. The setback standards are also intended to allow for flexibility in maintaining existing structures and in developing attached housing, consistent with the policies of the city’s comprehensive plan. Setbacks may be adjusted through the following means.
(1) Minor encroachments into a setback yard for chimneys, porches, decks, eaves and similar parts of a structure are permitted, pursuant to applicable building codes.
(2) The Planning Commission may reduce the required front yard setback requirement for a new or expanded building where it finds that one or more buildings on lots abutting the subject site and on the same block face (street frontage) have less than the minimum front yard setback. In such cases, the Commission may establish a minimum setback that is equal to the average front setback on the two abutting lots. Where only one building is on an abutting lot on the same block face, the Commission shall find the average using the standard setback and the setback of the existing building. The above exception does not apply to garage openings, carport entries and structures where vehicles are serviced, stored or repaired; the minimum street setback of 20 feet shall be maintained for those structures.
(Ord. 1267, passed 1-3-2012)