Outdoor fireplaces, fire pits, and similar devices fueled by natural gas or liquefied petroleum gas are allowed when approved by the Building and Fire Department and the device is designed to only burn a gas flame and not wood or other solid fuel. At one-and two-family dwelling units, combustible construction and flammable vegetation shall not be located within 10 feet of gas-fueled devices. At all other Group R occupancies, the minimum distance to combustible construction and flammable vegetation shall be 20 feet. Where chimneys or vents are installed, they shall have an approved spark arrester as defined in California Mechanical Code, Section 221.
(Ord. 584 § 1, 2022)