§ 51.10 INDEPENDENT SEWER FOR EACH BUILDING; EXCEPTIONS.
   A separate and independent building sewer shall be provided for every building; except where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard, or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one building sewer. A permitted and engineered six-inch trunk line shall be constructed to serve both properties spitting off in two individual four-inch services. The said services shall divide at one clean out per property and divide by a six-inch by four-inch split wye connection. The trunk line up to the cleanout per property is to be owned and maintained by the town.
(1982 Code, § 5-2010) (Ord. passed 6-14-1965; Am. Ord. passed 11-1-2021) Penalty, see § 10.99