(A) General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as to be preserved safely, fire hazards eliminated, and adjoining properties in the neighborhood protected from blighting influences.
(B) Protective treatment. All exterior surfaces, including but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. All siding and masonry joints as well as those between the building envelope and the perimeter of windows, doors, and skylights shall be maintained weather resistant and water tight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. Those surface materials whose appearance and maintenance would be enhanced by a natural weathering effect or other natural effects may remain untreated.
(C) Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. The numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches in height with a minimum stroke width of 0.5 inch. Numbers shall not exceed a maximum of 24 inches in height. Address signage shall be no larger than necessary for adequate identification by safety service personnel.
(D) Structural members. All structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads.
(E) Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent entry of rodents and other pests.
(F) Exterior walls. All exterior walls shall be free from holes, breaks, and loose or rotting materials; and maintained weatherproofed and properly surface coated where required to prevent deterioration.
(G) Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain or melting snow or ice. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions.
(H) Decorative features. All cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition.
(I) Overhang extensions. All overhang extensions including, but not limited to canopies, marquees, signs, metal awnings, fire escapes, standpipes, and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces or metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
(J) Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads. Said areas shall be kept clear of hazards and debris and shall not be used as storage areas.
(K) Chimneys, towers and satellite dishes. All chimneys, cooling towers, smoke stacks, antennas, satellite dishes and similar appurtenances shall be maintained structurally safe and sound, and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
(L) Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.
(M) Window, skylight and door frames. Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight. All glazing materials shall be maintained free from cracks and holes.
(N) Doors. All exterior doors, door assemblies and hardware shall be maintained in good condition.
(O) Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water.
(P) Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents.
(Ord. 15-2008, passed 10-1-08)