§ 151.047 VENTILATION.
   (A)   Habitable spaces. Every habitable space shall have at least one openable window.
   (B)   Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by division (A) above, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated.
   (C)   Cooking facilities. Unless approved through the certificate of occupancy, cooking shall not be permitted in any rooming unit or dormitory unit, and a cooking facility or appliance shall not be permitted to be present in a rooming unit or dormitory unit. Exception: where specifically approved in writing by the property maintenance code official.
   (D)   Process ventilation. Where injurious, toxic, irritating, or noxious fumes, gases, dusts, or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space.
   (E)   Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted in accordance with the manufacturer’s instructions. Exception: listed and labeled condensing (ductless) clothes dryers.
(Ord. 2010-3, passed 8-31-2010)