1141.03 LOT AREA, FRONTAGE AND YARD REQUIREMENTS.
   (a)   The following minimum requirements shall be observed subject to the modified requirements contained in Section 1157.03.
 
SCHEDULE OF MINIMUM LOT, FRONTAGE AND YARD SIZES





Use




Lot Area (Sq.Ft.)


Lot Area Per Family (Sq.Ft.)


Minimum Required Front Yard Depth (Ft.)
Lot Width at Min- imum Required Front Yard Depth (Ft.)

Side Yard Least Width (Ft.)


Widths Sum of Widths (Ft.)


Rear Yard Depths (Ft.)
Single Family (R-1-60) 1 & 1-1/2 stories
7,500
7,500
40
60
8
20
40
(R-1-80) 2 & 2-1/2 stories
10,000
10,000
40
80
10
25
50
Other Permitted Uses
15,000
40
80
16
35
40
1 & 1-1/2, 2 & 2-1/2 stories
15,000
40
80
22
50
40
 
(Ord. 11-71. Passed 5-25-71.)
   (b)   A minimum 1200 square feet of living floor area and construction of at least a one car garage.
(Ord. 24-01. Passed 8-28-01.)
   (c)   Minimum Foundation Requirements.
      (1)   Foundation walls to be minimum of 8" thick except 12" block will be required on foundation wall subject to pressures greater than expected by ordinary back fill (i.e., hillsides, high water table etc.)
      (2)   All 8"foundation footers shall be 16" wide and 8" thick.
      (3)   Footers under 12" walk to be 20" wide by 8" deep.
      (4)   All footers must be below frost level at exposed evaluation (three foot).
      (5)   There shall be a minimum of eleven (11) courses of block on all required foundations including both 8" block and 12" block walls.
   Individuals of builders where zoning application is denied by the Zoning Inspector due to failure to meet said requirements may file an application for a building variance which will be heard by the Board of Zoning Appeals in accordance with Village Zoning variance procedures. (Ord. 27-02. Passed 8-13-02.)