All aluminum siding installations to structures in the Municipality, shall be grounded as a safety factor to protect public safety, health and general welfare, and the following standards are hereby adopted:
The entire perimeter of structure shall be grounded on opposite ends.
(a) Aluminum mesh shall be installed on all corners for continuity of ground 10 feet high from grade level.
(b) Ground to street side of water meter.
(c) Ground to nearest cold water line for opposite end grounding.
(d) Install ground jumper for "c" to street side of water meter.
(e) 3/4" ground rod driven into ground 8 feet will be allowed by special permission of the Building Inspector.
Material approved:
Aluminum mesh 2' x 10'
1/4" cadmium plated bolt
1/4" pan head aluminum screws
#6 ground wire
Ground clamps to water pipes
Rod 3/4" x 8'. (Ord. 833-61. Passed 4-4-61.)