§ 150.040 AMENDMENTS TO INTERNATIONAL PLUMBING CODE.
   The International Plumbing Code, 2018 Edition, hereinafter referred to as the "Code", and adopted by the provision of this chapter, is hereby amended, altered, changed, and modified as follows:
   Section 101.1, Title of the Code is hereby amended by designating the name of the jurisdiction to be the "City of McCook, Nebraska, a municipal corporation."
   Section 103.2, Appointment of the Code is hereby amended to read as follows:
   Any reference in this Code to "Code Official" shall mean the Building Official. The Building Inspector and other assistants, clerks, and employees appointed by the Building Official to administer this Code shall have such powers as designated by the Building Official.
   Section 103.3 of the Code is hereby deleted.
   Section 106.6.2, Fee schedule of the Code is hereby amended to read as follows:
   Any person desiring a plumbing permit shall at the time of filing an application therefore pay to the City of McCook a fee set by ordinance of the City Council and set forth in Chapter 38, Fee Schedule.
   Section 608.16.4.2, of the code is hereby deleted.
   Section 608.17.5, Connections to lawn irrigation systems is hereby amended to read as follows:
   Section 608.17.5 Connections to lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by a check valve, an atmospheric-type vacuum breaker, a pressure-type vacuum breaker assembly, or a reduced pressure principle backflow prevention assembly. Valves shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principle backflow prevention assembly.
   Section 903.1, Roof extension is hereby amended to read as follows:
   903.1 Roof extension. Open vent pipes that extend through a roof shall be terminated not less than 12 inches above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall terminate not less than 7 feet above the roof.
(Ord. 2005-2734, passed 7-18-2005; Ord. 2009-2831, passed 9-21-2009; Ord. 2016-2928, passed 5-16-2016; Ord. 2020-2996, passed 2-17-2020)