§ 154.132 DRAWING SPECIFICATIONS.
   The preliminary plat shall be drawn with waterproof non-fading black ink or legibly drawn with pencil on tracing cloth or tracing paper of good quality at a scale of not more than 100 feet to the inch, and shall show correctly on its face the following information:
   (A)   Date, scale and north point;
   (B)   The proposed subdivision name (must be the same as that specified in the application);
   (C)   The name and address of the owner, the subdivider and the surveyor preparing the plat;
   (D)   Location of the subdivision by government lot, quarter section, section, township, range and county;
   (E)   A vicinity sketch or small-scale drawing of the section or area within which the subdivision lies, with the location of the subdivision indicated thereon;
   (F)   The exact length and bearing of the exterior boundaries of the subdivision. Dimensions shall be expressed in feet and decimals of a foot;
   (G)   Location and names of adjacent subdivisions and the owners of adjoining parcels of unsubdivided land;
   (H)   Zoning on and adjacent to the subdivision;
   (I)   Location, width and names of all existing and platted streets, alleys and other public ways and easements, railroad and utility rights-of-way, parks, cemeteries, watercourses, drainage ditches, permanent buildings, bridges and other pertinent data as determined by the Planning and Zoning Board;
   (J)   The water elevations of adjoining lakes or streams at the date of the survey and the approximate high and low water elevations of such lakes or streams. All elevations shall be referred to the village datum plane;
   (K)   If the subdivision borders a lake, river or stream, the distances and bearings of a meander line established not less than 20 feet back from the ordinary high water mark of such waterways;
   (L)   Layout, width and grades of all new streets and rights-of-way, including alleys, highways, easements for sewers and water mains and other public utilities;
   (M)   Existing sewers, water mains, culverts and other underground structures within the tract or immediately adjacent thereto. The location and size of the nearest water main and sanitary and storm sewers are to be indicated in a general way upon the preliminary plat;
   (N)   Plans of proposed utility layouts (water, sewers and storm drains) showing connections to any existing or proposed utility systems;
   (O)   Approximate dimensions and areas of lots;
   (P)   Approximate radii of all curves, length of tangents and central angles on all streets;
   (Q)   Approximate location and area of all property proposed to be dedicated or reserved for public use or to be reserved by deed covenant for use of all property owners in the subdivision, with the conditions, if any, of such dedication or reservation;
   (R)   Contours at vertical intervals of not more than one foot or at more frequent intervals if required by the Planning and Zoning Board for land with unusual topography;
   (S)   Street profile plans for all existing and proposed streets, containing information specified by the Planning and Zoning Board; and
   (T)   Such other requirements or specifications as the Village Engineer, Planning and Zoning Board or Village Board may deem necessary or desirable.
(Ord. 1999-2, Subdivisions § 6, subs. .030, passed 2-15-1999)