Zoning District | Minimum Lot Size | Maximum Building Height Space | Minimum Yard Setback | Maximum Lot Coverage |
Zoning District | Minimum Lot Size | Maximum Building Height Space | Minimum Yard Setback | Maximum Lot Coverage | |||||
Area (square feet) | Lot width (feet) | Stories | Feet | Front (feet) | Side | Rear (feet) | |||
Least (feet) | Total (feet) | ||||||||
Agriculture, AG (see A, E, F, and H below) | 1 acre | 150 | 2 1/2 | 35 (75 farm buildings) | 50 | 20 | 25 | 50 | 10% |
Single-Family Residential, Low Density, R-1A (see A, E, F, and H below) | 1 acre | 100 | 2 1/2 | 35 | 25 | 10 | 25 | 35 | 25% |
Single-Family Residential, Medium Density, R-1B (see A, E, F, and H below) | 13,000 | 90 | 2 1/2 | 35 | 25 | 8 | 23 | 35 | 30% |
Multiple-Family Residential, Low Density, R-2 (see A, B, D, E, and H below) | SF: 13,000 | 90 | 2 1/2 | 35 | 25 | 8 | 20 | 35 | 30% |
2F: 20,000 | 120 | 2 1/2 | 35 | 25 | 8 | 20 | 35 | ||
MF: 20,000 | 120 | 2 1/2 | 35 | 35 | 10 | 25 | 35 | ||
Multiple-Family Residential, Medium Density, R-3 (see A, C, D, E, F, and G below) | SF: 13,000 | 90 | 2 1/2 | 35 | 25 | 8 | 20 | 35 | 35% |
2F: 20,000 | 120 | 2 1/2 | 35 | 25 | 8 | 20 | 35 | ||
MF: 5 acres | 300 | 2 1/2 | 35 | 50 | 20 | 50 | 50 | ||
Mobile Home Park, MHP (see A and E below) | 10 acres | See § 151.071 | 2 1/2 | 35 | See § 151.071 | ||||
Office Service, OS (see A and E below) | 5,000 | 50 | 21/2 | 35 | 25 | 10 | 20 | 15 | 30% |
General Commercial, C-2 (see A and E below) | 20,000 | 100 | 2 1/2 | 35 | 35 | 10 | 20 | 35 | 25% |
Central Business District, CBD (see A, E, and G below) | - | - | 3 | 45 | - | - | - | - | - |
Limited Industrial, I-1 (see A and E below) | 1 acre | 150 | 2 | 40 | 50 | 50 | 100 | 35 | 30% |
General Industrial, I-2 (see A and E below) | 3 acres | 200 | 2 | 40 | 85 | 50 | 100 | 50 | 25% |
NOTES TO TABLE: SF: - Single-Family Dwellings 2F: - 2-Family Dwellings MF: - Multiple-Family Dwellings A - All dwelling units and occupied buildings shall be served with a public water supply system and a public sanitary sewer system. B - Every lot or parcel of land occupied by a low density multiple-family structure shall contain a minimum of 20,000 square feet and a total area of not less than the following: Unit Type Lot Area/Dwelling Unit Efficiency 4,800 square feet 1 bedroom 6,000 square feet 2 bedrooms 6,700 square feet Every additional bedroom 1,300 square feet C - Every lot or parcel of land occupied by a medium density multiple-family dwelling structure shall contain a minimum area of 5 acres and a total area of not less than the following: Unit Type Lot Area/Dwelling Unit Efficiency 1,900 square feet 1 bedroom 2,300 square feet 2 bedrooms 3,000 square feet Every additional bedroom 700 square feet D - In addition to the required setbacks from property boundaries, the following minimum distances shall be required between each multiple family structure: (a) Where buildings are front to front or front to rear, 3 times the height of the taller building, and not less than 70 feet; (b) Where buildings are side to side, 1.5 times the height of the taller building, but not less than 20 feet; and (c) Where buildings are front to side, rear to side, or rear to rear, 2 times the height of the taller building but not less than 35 feet. In applying the above standards, the front of the building shall mean that the face of the building having greatest length and contains the primary entrance to the building; the rear is that face opposite the front. The side is the face having the smallest dimension. E - The minimum distance of any principal building from the ordinary high water mark shall be 50 feet. F - Driveways to single-family dwellings shall be located in the greater side yard setback. G - Any structure located within the CBD which abuts a dwelling located within the AG, R-1A, or R-1B District shall have a minimum setback from the common property line of 10 feet. | |||||||||
H - The minimum floor area of dwelling units shall be as follows: Type of Dwelling Total Usable Floor Area (square feet) 1-family 1,000 2-family, per dwelling unit 800 Multiple-family: Efficiency Unit 500 1 bedroom unit 700 2 bedroom units 900 3 bedroom units 1,100 4 bedroom units 1,300 Each additional bedroom 90 | |||||||||
(Ord. 239, passed 3-5-2001, § 4.5)