§ 52.128 MATERIAL SPECIFICATIONS.
   The building connection outside the exterior face of any building or similar structure shall conform to the requirements of this chapter and the Department Regulations as to permits, materials, and workmanship. Building connections, for gravity applications, shall be constructed of extra-strength vitrified clay pipe conforming to ATSM Specification C-700; extra heavy cast-iron soil pipe conforming to ASTM Specification A-74; ductile iron pipe conforming to ANSI/AWWA A021.5V C-151, Class 52 or polyvinyl chloride pipe conforming to ASTM D-3034, SDR 35. For building connections larger than 10 inch diameter, reinforced concrete pipe conforming to ASTM Specification C-76, Class IV, Wall B shall be used. Building sewer force mains shall be constructed of ductile iron pipe conforming to ANSI/AWWA A-21.51/C-151, Class 53 or polyvinyl chloride pipe conforming to ASTM D-2241, SDR 26. Building sewer force mains shall be laid as to maintain a continuous positive slope from the building to the point of discharge unless vacuum relief valves and clean outs are installed at high and low points, respectively. Asbestos cement pipe and no-hub cast iron pipe will not be allowed for the installation of or repair of any building connection.
(Ord. passed 1-17-95) Penalty, see § 52.999