SEC. 91.5.900. BASIC PROVISIONS.
   (Amended by Ord. No. 186,488, Eff. 12/27/19.)
 
   Chapter 9 of the CRC is hereby adopted by reference except as amended or modified herein. Section R902.2 of the 2019 California Residential Code is not adopted.
 
91.5.902.2. Fire-retardant-treated Shingles and Shakes. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 for use on Class A, B or C roofs. Fire-retardant-treated wood shakes and shingles shall comply with ICC-ES EG107 and with the weathering requirements contained in California Health and Safety Code Section 13132.7(j). Each bundle shall bear labels from an ICBO accredited quality control agency identifying their roof-covering classification and indicating their compliance with ICC-ES EG107 and with the weathering requirements contained in California Health and Safety Code Section 13132.7(j).
 
   No wood shake or shingle roof covering is permitted as provided by LAMC Subsection 91.1505.1.