Skip to code content (skip section selection)
Compare to:
Loading...
DIVISION 35
REFERENCED STANDARDS
 
(Division Title Amended by Ord. No. 185,587, Eff. 7/16/18.)
 
 
Section
91.3500   Basic Provisions.
 
 
SEC. 91.3500. BASIC PROVISIONS.
 
   Chapter 35 of the CBC is hereby adopted by reference.
 
 
 
 
DIVISION 61
SPECIAL HAZARD AREAS
 
(Div. 61 Title Amended by Ord. No. 165,310, Eff. 12/31/89.)
 
 
Section
91.6101   Impact Hazard Glazing in Existing Buildings.
91.6102   Rubbish Rooms.
91.6103   Shafts, Pits and Similar Excavation – Misdemeanor.
91.6104   Fire Districts.
91.6105   Separation from Oil Wells.
91.6109   Swimming Poolsand Other Bodies of Water – Protective Devices Required.
 
 
SEC. 91.6101. IMPACT HAZARD GLAZING IN EXISTING BUILDINGS.
   (Title and Section Amended by Ord. No. 179,324, Eff. 12/10/07, Oper. 1/1/08.)
 
91.6101.1. Impact Hazard Glazing in Existing Buildings. When application is made for a permit for alterations, repairs or additions to real property, the permit shall be withheld until the department receives a sworn affidavit from the real property owner stating that:
 
   1.   Prior to final inspection of the work under the permit, the owner shall replace the glass in every existing sliding glass panel of sliding-type doors, other than wardrobe doors and bathroom shower doors and French-type wooden doors, in the residential portion of the building with approved safety glazing pursuant to CBC Section 2406; or
 
   2.   The owner declares the existing glazing of the glass in every sliding glass panel of sliding-type doors, other than wardrobe doors and bathroom shower doors and French-type wooden doors, in the residential portion of the building complies with the safety glazing requirements pursuant to CBC Section 2406.
 
   EXCEPTION: The owner may install film on the glass in every existing sliding glass panel of sliding-type doors, other than wardrobe doors and bathroom shower doors and French-type wooden doors, in the residential portion of the building with film approved by the department.
 
91.6101.2. Application. The provisions of this section shall apply only in the following circumstances:
 
   1.   To Group R-3 Occupancy, if a permit is issued with a valuation of $10,000 or more per unit for alterations, repairs or additions;
 
   2.   To Group R-1, R-2, R-3.1 or R-4 Occupancy, if a permit is issued for $3,000 or more per dwelling unit and/or guest room for alterations, repairs or additions;
 
   3.   To an individual unit of Group R-1, R-2, R-3.1 or R-4 Occupancy, townhouse or condominium, if a permit is issued for $10,000 or more for alterations, repairs or additions to that individual unit; and
 
   4.   To any Group R Occupancy that is sold or exchanged, including an individual townhouse or condominium unit.
 
 
SEC. 91.6102. RUBBISH ROOMS.
   (Former Sec. 91.6106 Redesignated by Ord. No. 165,310, Eff. 12/31/89.)
 
   Every room, except a room in a Group R, Division 3 Occupancy, appropriated for the storage or treatment of combustible rubbish, shall be of one-hour fire-resistive construction. All openings in interior partitions shall be protected by a fire assembly having a one-hour fire-resistive rating. All openings in exterior walls shall be protected by a fire assembly having a three-fourths hour fire-resistive rating.
 
 