§ 22.198 VIBRATION.
   (A)   Maximum vibration. Ground-transmitted vibration shall not exceed the maximum permitted particle velocities in Table 24 at the locations specified therein.
   (B)   Measurement.  
      (1)   A seismograph or other three-component measuring system capable of simultaneous measurement of vibration in three mutually perpendicular directions shall be used to measure vibration.
      (2)   Particle velocity may be measured directly or computed by the following formula:
   PV = 6.28 x F x D
         PV:    Particle velocity in inches per second
         F:       vibration frequency in cycles per second
         D:       single amplitude displacement of the vibration in inches
      (3)   The maximum particle velocity shall be the maximum vector sum of the three mutually perpendicular components recorded simultaneously.
(Ord. 480B, passed 8-21-1953; Ord. 90-O-036, passed 11-8-1990; Ord. 14-O-36, passed 11-14-2014)
 
Table 24: Maximum Ground Transmitted Vibration
Maximum Permitted Particle Velocity*
Use
At Adjacent Lot Line
At Nearest Residentially Zoned Lot Boundary **
Heavy Industrial
0.2
0.02
Other
0.1
0.02
*   Where vibration is produced as discrete impulses (impact vibrations) not exceeding 100 per minute, maximum permitted velocities may be doubled
**   Between 7:00 a.m. and 7:00 p.m., maximum permitted velocity at residentially zoned lot boundaries shall be reduced 50%
 
(Ord. 480B, passed 8-21-1953; Ord. 90-O-036, passed 11-8-1990; Ord. 14-O-36, passed 11-14-2014)