Allowable Span of Headers in Feet for Bearing Walls | |||||
Size of Steel Header | Size of Wood Header | No Story Above | One Story Above | Two Stories Above | Allowable Span of Headers in Garages or in Walls Not Supporting Floors or Floor |
Allowable Span of Headers in Feet for Bearing Walls | |||||
Size of Steel Header | Size of Wood Header | No Story Above | One Story Above | Two Stories Above | Allowable Span of Headers in Garages or in Walls Not Supporting Floors or Floor |
2-1/2 x 2-1/2 x 1/4 | 2–2 in. x 4 in. | 4 ft. | 6 ft. | ||
3-1/2 x 3-1/2 x l/4 | 2–2 in. x 6 in. | 4 ft. to 6 ft. | 4 ft. | 6 ft. to 8 ft. | |
6 x 1-7/8 JR | 2–2 in. x 8 in. | 6 ft. to 8 ft. | 4 ft. to 6 ft. | 8 ft. to 10 ft. | |
4 x 2-5/8 | 2–2 in. x 10 in. | 8 ft. to 10 ft. | 6 ft. to 8 ft. | 4 ft. to 6 ft. | 10 ft. to 12 ft. |
7 x 2-1/8 JR | 2–2 in. x 12 in. | 10 ft. to 12 ft. | 8 ft. to 10 ft. | 6 ft. to 8 ft. | 12 ft. to 14 ft. |
2–2 in. x 14 in. | 12 ft. to 14 ft. | 10 ft. to 12 ft. | 8 ft. to 10 ft. | 14 ft. to 16 ft. | |
Note: Garage headers carrying roof or ceiling loads may be of 2, 2-inch by 14-inch with a flitch plate of steel or plywood, bolted between the 2-inch by 14-inch, if specified by the architect | |||||
(Prior Code, § 9-123) (Ord. 94-11B, passed 4-21-1994)