§ 150.199 MAXIMUM ALLOWABLE SPAN FOR HEADERS SUPPORTING WOOD FRAME WALLS.
Allowable Span of Headers in Feet for Bearing Walls
Size of Steel Header
Size of Wood Header
No Story Above
One Story Above
Two Stories Above
Allowable Span of Headers in Garages or in Walls Not Supporting Floors or Floor
Allowable Span of Headers in Feet for Bearing Walls
Size of Steel Header
Size of Wood Header
No Story Above
One Story Above
Two Stories Above
Allowable Span of Headers in Garages or in Walls Not Supporting Floors or Floor
2-1/2 x 2-1/2 x 1/4
2–2 in. x 4 in.
4 ft.
6 ft.
3-1/2 x 3-1/2 x l/4
2–2 in. x 6 in.
4 ft. to 6 ft.
4 ft.
6 ft. to 8 ft.
6 x 1-7/8 JR
2–2 in. x 8 in.
6 ft. to 8 ft.
4 ft. to 6 ft.
8 ft. to 10 ft.
4 x 2-5/8
2–2 in. x 10 in.
8 ft. to 10 ft.
6 ft. to 8 ft.
4 ft. to 6 ft.
10 ft. to 12 ft.
7 x 2-1/8 JR
2–2 in. x 12 in.
10 ft. to 12 ft.
8 ft. to 10 ft.
6 ft. to 8 ft.
12 ft. to 14 ft.
2–2 in. x 14 in.
12 ft. to 14 ft.
10 ft. to 12 ft.
8 ft. to 10 ft.
14 ft. to 16 ft.
Note:   Garage headers carrying roof or ceiling loads may be of 2, 2-inch by 14-inch with a flitch plate of steel or plywood, bolted between the 2-inch by 14-inch, if specified by the architect
 
(Prior Code, § 9-123) (Ord. 94-11B, passed 4-21-1994)