A. Vibrations from any operation or activity shall not exceed the displacement values below.
B. Vibration displacements shall be measured with an instrument capable of simultaneously measuring in three (3) mutually perpendicular directions. The maximum vector resultant shall be less than the vibration displacement permitted. The maximum displacements shall be determined by the following formula:
D = K/f, where
D = displacement in inches
K = a constant given in table 5H-1 below
f = the frequency of the vibration transmitted through the ground in cycles per second
Zone | Point Of Measurement | Continuous | Impulsive (At Least 1 Second Rest Between Pulses That Do Not Exceed 1 Second Duration) | Less Than 8 Pulses Per 24 Hour Period |
All zones, except industrial | At lot lines | 0.003 | 0.006 | 0.015 |
Industrial zones | At industrial zone boundary line | 0.030 | 0.060 | 0.150 |
At the boundary of residential zones, recreational areas, or educational facilities | 0.003 | 0.006 | 0.015 |
(Ord. 05-4186, 12-15-2005)