1337.06 SATELLITE SIGNAL RECEIVING EARTH STATIONS AND PARABOLICS SUPPORT STRUCTURES.
   (a)    The structure must be in conformance with the National Electrical Code, Article 800 and all other regulations or requirements imposed by law.
   (b)    Only metal support, galvanized construction shall be used in an earth station.
   (c)    The maximum diameter of any earth station shall not exceed twelve feet.
   (d)    Only a concrete base shall be employed and in line with grade.
   (e)    The maximum height of any earth station shall be fifteen feet from grade level.
   (f)   The structure, including foundation, shall be designed to withstand wind force of up to seventy miles per hour in conformance with generally accepted engineering practices.
   (g)    Any driving motor shall be limited to 110-volt maximum power design and shall be encased in protective guards and shall at all times be in compliance with requirements as provided in the National Electrical Code, Article 800 and any other requirements as provided by law.
   (h)    All wiring shall be underground and shall be encased in approved PVC conduit or rigid conduit with eighteen-inch cover.
   (i)    The earth station shall be bonded to an eight-foot grounding rod and in accordance with the requirements as provided in the National Electrical Code.
   (j)    The earth station shall be manufacturer's standard color and shall contain no graphics or advertising.
(Ord. 1985-29. Passed 11-25-85.)