1335.01 EMERGENCY EGRESS OPENINGS.
   (a)    Every sleeping room shall have at least one operable window or exterior door approved for emergency egress or rescue. The units shall be operable from the inside to a full clear opening without the use of separate tools. Where windows are provided as a means of egress or rescue they shall have a sill height of not more than forty-four inches above the floor.
   (b)    All egress or rescue windows from sleeping rooms shall have a minimum net clear opening of 5.7 square feet. The minimum net clear opening height dimension shall be twenty-four inches. The minimum net clear opening width dimension shall be twenty inches.
   (c)    Grade floor windows shall have a minimum net clear opening of five square feet.
(Ord. 1992-101. Passed 1-14-92.)