The number of off-street parking spaces required shall be as set forth in the following:
Use | Parking Spaces Required |
Automobile or Machinery sales and service garages | 1 for each 600 sq. ft. floor area |
Automobile car wash, automatic | Two per site in addition to required stacking spaces. A washing space is not a parking space. |
Automobile car wash, self-service | No parking space is required; one drying space plus two stacking spaces are required per washing space. A washing space is not a parking place. |
Banks, business and professional offices | 1 for each 500 sq. ft. floor area |
Bowling alleys | 4 for each alley |
Churches | 1 for each 4 seats in the sanctuary |
Dance halls and assembly halls without fixed seats; exhibition halls except church assembly rooms in conjunction with auditorium | 1 for each 100 sq. ft. of floor area used for assembly or dancing |
Dwellings (not including garage) | Single family - 4 spaces per dwelling Multi-family- 2 spaces per one bedroom unit 3 spaces per two bedroom unit 4 spaces per three bedroom unit |
Funeral homes, mortuaries | 1 for each 50 sq. ft. of floor area |
Furniture and appliance stores, household equipment or furniture repair shop over 1,000 sq. ft. floor area | 1 for each 500 sq. ft. of floor area |
Hospitals | 2 for each bed |
Hotels, motels and bed and breakfast | 1 for each bedroom |
Libraries, museums or art gallaries | 1 for each 400 sq. ft. of floor area |
Manufacturing plants, research or testing laboratories, bottling plants, over 1,000 sq. ft. in area | 1 for each employee in the maximum shift |
Medical or dental clinics | 1 for each 200 sq. ft. of floor area |
Restaurants, taverns and night clubs, of over 1,000 sq. ft. floor area | 1 for each 200 sq. ft. of floor area |
Retail stores, shops, etc., of over 2,000 sq. ft. of floor area | 1 for each 250 sq. ft. of floor area |
Convalescent and nursing homes | 1 for each 2 beds |
Sports arenas, auditoriums, theaters, assembly halls, other than schools | 1 for each 4 seats |
Wholesale establishments or warehouses | 1 for each employee on maximum shift or 1 for each 3,000 sq. ft. of floor area, whichever is greater. |
High school, business, technical and trade school, college and university | 1 for each 2 students |
Elementary and middle schools | 2 per classroom and 1 for each 60 sq. ft. of gross floor area in the auditorium or multi-purpose room. |
(Ord. 2-00. Passed 3-20-00.)