17.08C.040.05: TABLES AND INFORMATION SHEETS:
The figures and information sheets shall be incorporated into this article as guidelines for the public and the city. The city does not endorse or discriminate against any manufacturer or company that may be shown, portrayed or mentioned by the examples.
   FIGURE 1
 
   TABLE 1
Lamp Type
Initial Lumen Output
Lamp Wattage
Lamp Type
Initial Lumen Output
Lamp Wattage
Incandescent lamp (frosted) (Syl.)
25
235
Incandescent lamp (frosted) (Syl.)
40
375
Incandescent lamp (frosted) (Syl.)
60
89
Incandescent lamp (frosted) (Syl.)
100
1,690
Incandescent lamp (frosted) (Syl.)
150
2,850
Incandescent flood or spot (G.E.)
75
765
Incandescent flood or spot (G.E.)
120
1,500
Incandescent flood or spot (G.E.)
150
2,000
Quartz halogen lamp (frosted) (Syl.)
42
665
Quartz halogen lamp (frosted) (Syl.)
52
885
Quartz halogen lamp (frosted) (Syl.)
72
1,300
Quartz halogen lamp (frosted) (Syl.)
300
6,000
Quartz halogen lamp (frosted) (Syl.)
500
10,500
Quartz halogen lamp (frosted) (Syl.)
1,000
21,000
Quartz halogen mini flood or spot (G.E.) (12 volt MR-16 type)
20
260
Quartz halogen mini flood or spot (G.E.) (12 volt MR-16 type)
42
630
Quartz halogen mini flood or spot (G.E.) (12 volt MR-16 type)
50
895
Quartz halogen mini flood or spot (G.E.) (12 volt MR-16 type)
75
1,300
Fluorescent lamp (Phillips)
7
400
Fluorescent lamp (Phillips)
9
600
Fluorescent lamp (Phillips)
13
900
Fluorescent lamp (Phillips)
22
1,200
Fluorescent lamp (Phillips)
28
1,600
Fluorescent lamp (G.E. cool white)
40
3,150
Low pressure sodium lamp (Phillips)
18
1,800
Low pressure sodium lamp (Phillips)
35
4,800
Low pressure sodium lamp (Phillips)
55
8,000
Low pressure sodium lamp (Phillips)
90
13,500
Low pressure sodium lamp (Phillips)
135
22,500
Low pressure sodium lamp (Phillips)
180
33,000
High pressure sodium lamp (diffuse) (G.E.)
35
2,250
High pressure sodium lamp (diffuse) (G.E.)
50
4,000
High pressure sodium lamp (diffuse) (G.E.)
70
6,400
High pressure sodium lamp (diffuse) (G.E.)
100
9,500
High pressure sodium lamp (diffuse) (G.E.)
150
16,000
High pressure sodium lamp (diffuse) (G.E.)
250
27,500
High pressure sodium lamp (diffuse) (G.E.)
400
50,000
Mercury vapor lamp (white deluxe) (Syl.)
100
4,500
Mercury vapor lamp (white deluxe) (Syl.)
175
8,500
Mercury vapor lamp (white deluxe) (Syl.)
250
11,100
Mercury vapor lamp (white deluxe) (Syl.)
400
20,100
Metal halide lamp (coated) (G.E.)
32
2,500
Metal halide lamp (coated) (Venture)
50
3,400
Metal halide lamp (coated) (G.E.)
100
9,000
Metal halide lamp (coated) (G.E.)
175
15,750
Metal halide lamp (coated) (G.E.)
250
20,500
Metal halide lamp (coated) (G.E.)
400
36,000
 
Table 2 of this section lists the maximum lumen levels guidelines at various heights above ground level. The maximum lumens levels should only be exceeded if there are design constraints or other site specific factors that would jeopardize safety. A detailed explanation for lumen amounts in excess of the guidelines shall be provided by the owner/occupant or developer.
   TABLE 2
   MOUNTING HEIGHT/LAMP OUTPUT RECOMMENDATIONS
Mounting Height (Feet)
Max Lumens
Mounting Height (Feet)
Max Lumens
6
1,000
8
1,600
10
2,000
12
2,400
16
6,000
20
8,000
24
9,000
28
12,000
32
24,000
36
28,000
40 or more
32,000
 