1276.03  PREPARATION.
   (a)   Site development plans shall be  prepared by persons professionally qualified to do such work.  Final site plans shall be certified by an architect, engineer or  land surveyor duly registered by the State of Ohio.
   (b)   Every site plan shall show the name of the development, the name and address of the owner and developer, and the north point, date, scale and number of sheets.
   (c)   Site development plans shall be prepared at a scale of one inch equals fifty feet or larger.  No sheet shall exceed forty-two inches in size.  Six copies shall be submitted to the Planning and Zoning Department for plans which are to be reviewed by the Planning Commission and six copies for plans which are to be reviewed by the Administrator.
   (d)   A site development plan may be prepared on one or more sheets to show clearly the information required by this section and to facilitate the review and approval of the plan.  If such a plan is prepared on more than one sheet, match lines shall clearly indicate where the several sheets join.
   (e)   Profiles must be submitted on standard plan profile sheets.  Special studies,  as required, may be submitted on standard cross-section paper and shall have a scale of one inch equals fifty feet horizontally and one inch equals five feet vertically.  No sheet size shall exceed forty-two inches.  Flood plain limit studies required by this Zoning Code shall be shown on all profile sheets with reference to properties affected the centerline of a stream.
   (f)   All horizontal distances shown on the site plan shall be in feet and decimals of a foot, to the closest tenth of a foot, and all bearings shall be in degrees, to the nearest ten seconds. 
(Ord. 2337.  Passed 10-20-92.)