§ 154.706 VIBRATION.
   Earth borne vibrations from any operation or activity shall not exceed the displacement values shown in Table 154.706.1. Vibration displacements shall be measured with an instrument capable of simultaneously measuring in three mutually perpendicular directions. The maximum vector resultant shall be less than the vibration displacement permitted. The maximum displacements shall be determined by the following formula:
D = K
f
where:
D = displacement in inches
K = a constant given in Table 154.706.1
f = the frequency of the vibration transmitted through the ground in cycles per second
 
TABLE 154.706.1
VIBRATION PERFORMANCE STANDARDS
Zone and Place of Measurement
Continuous
Impulsive(at least 1 second rest between pulses which do not exceed 1 second duration)
Less Than 8 Pulses Per 24-Hour Period
Commercial and Industrial Zoning Districts:
0.003
0.006
0.015
At Lot Line
Industrial Zoning Districts
1.   At Zone Boundary Line
0.030
0.060
0.015
2.   At Residential Zone, Recreation Area or School Boundary Line
0.003
0.006
0.015
 
(Ord. O-05-04, passed 4-11-05)