§ 156.10 DRAINAGE.
   (A)   (1)   Where the pool is not provided with adequate syphon or pumpage drainage facilities, it shall be provided with at least one metal grated outlet situated at the lowest level or deepest end for drainage of pool water and for backwash disposal. The drain pipe shall be equipped with a valve located outside the walls of the pool. Such pipe or syphon or pumpage facilities shall be connected to a storm sewer when such storm sewer is located in any easement, alley or street adjacent to the lot upon which the pool is located. In the event no storm sewer is available, such connection shall be made with a sanitary sewer.
      (2)   All connections with either the storm sewer or the sanitary sewer shall be made only with the approval of the Board of Public Works. Upon inspection of the premises, the Building Commissioner may require the discharge of pool water into a dry well or series of dry wells or other dispersion point, provided that such water does not overflow onto any adjoining property.
   (B)   Pool water discharged into a brook or stream must comply with the disinfection and bacteriological regulations issued by the Health Officer of the city.
('74 Code, § 27-20) (Ord. G-61, passed - - ) Penalty, see § 156.99