(A) Building height limit. No building shall exceed 75 feet in height.
(B) Required lot area.
(1) No multiple-family dwelling shall be constructed on a lot having less than 6,000 square feet.
(2) Except as otherwise provided, each multiple-family dwelling shall be located on a lot having a minimum of 800 square feet of open space for each dwelling unit housed thereon.
(3) The open space requirement for multiple-family dwellings containing one-bedroom or efficiency units shall be 700 square feet for each dwelling unit.
(4) Solely for the purpose of determining compliance with lot area per dwelling unit requirements, each lodging room in a group dwelling shall be considered as one-half a dwelling unit.
(C) Percentage of lot coverage. All buildings, including accessory buildings, shall not cover more than 50% of the area of the lot.
(D) Yards required. Each lot shall have front, side and rear yards of not less than the depths or widths following:
(1) Front yard depth: 25 feet;
(2) Rear yard depth: 25 feet, or equal in depth to the height of the building, whichever is greater; and
(3) Side yards: Five feet, but each side yard shall be equal to one-fourth of the height of the building. For townhouses, the side yard requirements do not apply to common walls.
(E) Required court dimensions. The minimum dimension of a building containing an inner court shall be not less than one-half of the height of the building which contains the court.
(Prior Code, § Q-5-806) Penalty, see § 159.999