§ 155.078  NOISE.
   (A)   At no point on the boundary of the I-2 Enclosed Industrial or I-3 Reserved Industrial District, or any district which permits an enclosed industrial use, shall the sound pressure level of any enclosed industrial use operation or plant (other than background noises produced by sources not under the control of this chapter) exceed the decibel limits in the following octave bands.
Enclosed Industrial Use
Octave Band Frequency (Cycles Per Second)
Maximum Permitted Sound Level (In Decibels) 125 Feet From District Adjoining Residence or Suburban District Boundaries
Maximum Permitted Sound Level (In Decibels) 125 Feet From District Adjoining Business District Boundaries
0 to 75
75
80
75 to 150
70
75
150 to 300
65
70
300 to 600
59
64
600 to 1200
53
58
1200 to 4800
48
53
2400 to 4800
48
49
Above 4800
41
46
 
   (B)   At no point 125 feet from the boundary of an I-l Open Industrial District, shall the sound pressure level of any open industrial operation or plant (other than background noises produced by sources not under the control of this chapter) exceed the decibel limits in the following octave bands.
Open Industrial Use
Octave Band Frequency (Cycles Per Second)
Maximum Permitted Sound Level (In Decibels) 125 Feet From District Adjoining Residence or Suburban District Boundaries
Maximum Permitted Sound Level (In Decibels) 125 Feet From District Adjoining Business District Boundaries
0 to 75
75
81
75 to 150
70
76
150 to 300
66
72
300 to 600
62
68
600 to 1200
57
63
1200 to 4800
53
59
2400 to 4800
49
55
Above 4800
45
51
 
   (C)   Sound levels shall be measured with a sound level meter and associated octave band analyzer or filter, manufactured in compliance with standards prescribed by the American Standards Association.
(Ord. CO-67-2, passed 2-21-67)  Penalty, see § 155.999