§ 5  STREET SPECIFICATIONS FOR LAYER THICKNESS FOR ASPHALT CONCRETE TOP AND BASE COURSES AND THE FOUNDATION STONE COURSE.
   LEGEND FOR § 5 FIGURE
CBR VALUE
STREET TYPE
TOTAL PROFILE THICKNESS (in inches)
ASPHALT SURFACE COURSE
(in inches)
ASPHALT BASE COURSE
(in inches)
ROCK/STONE FOUNDATION COURSE
(in inches)
3
Resident
13 ½
1 ½
4
6 - - #2
6 - - #53-73
Collect       
17 ½
1 ½
3
13
Arterial
19 ½
1 ½
4
14
4
Resident
11 ½
1
2 ½
8
Collect
14 ½
1 ½
3
10
Arterial
18 ½
1 ½
4
13
5
Resident
9 ½
1
2 ½
6
Collect
13 ½
1 ½
3
9
Arterial
17 ½
1 ½
3
13
6
Resident
9
1
2
6
Collect
13
1 ½
2 ½
9
Arterial
14 ½
1 ½
3
10
7
Resident
8
1
2
5
Collect
12
1 ½
2 ½
8
Arterial
13 ½
1 ½
3
9
8
Resident
8
1
2
5
Collect
11 ½
1
2 ½
8
Arterial
13
1 ½
2 ½
9
10
Resident
7 ½
1
1 ½
5
Collect
9 ½
1
2 ½
6
Arterial
12
1 ½
2 ½
8
15
Resident
6 ½
1
1 ½
4
Collect
9
1
2
6
Arterial
11 ½
1
2 ½
8
 
   The surface course mixture shall consist of ISHC § 402, Type III, Hot Asphalt Emulsion Pavement or § 403, No. 9 binder, Hot Asphalt Concrete Pavement.
   When the thickness required exceeds 2 inches, the mixture used shall be a base course, consisting of ISHC § 402, No. 53B, Hot Asphalt Concrete Pavement.
(Ord. CO-98-18, passed 1-11-99)