4-11-2: AMENDMENTS:
   (A)   Section R101.1 Insert: the village of Forest View.
Table R301.2 (1) Climatic And Geographic Design Criteria:
Ground Snow Load: 25.
Wind Design Speed (mph): 90.
Wind Design Topographic Effects: No.
Wind Design Special Wind Region: No.
Wind Design Wind-Borne Debris Zone: No.
Seismic Design Category: A.
Subject To Damage From Weathering: Severe.
Subject To Damage From Frost Line Depth: 42".
Subject To Damage From Termite: n/a.
Winter Design Temp: 0.
Ice Barrier Underlayment Required: Yes.
Flood Hazards: Entered the national flood insurance program on June 11, 1968.
Flood Hazards: Current flood plain map is dated August 19, 2008, panels 17031C0491J and 17031C492J.
Air Freezing Index: 1300.
Mean Annual Temp: 50.6.
Section P2603.5.1 Sewer Depth. Building sewers that connect to private sewage disposal systems shall be not less than as required by the Illinois plumbing code inches (mm) below finished grade at the point of septic tank connection. Building sewers shall be not less than as required by the Illinois plumbing code inches (mm) below grade.
Section P2601.1 Scope: Delete existing language and insert:
The requirements for all plumbing systems shall be in accordance with the current edition of the Illinois plumbing code. Where the Illinois plumbing code does not address a specific issue, the requirements of chapter 26 shall apply.
   (B)   All existing homes in the village of Forest View shall be exempt from the requirements contained in section R313 Automatic Fire Sprinkler Systems and section P2904 Dwelling Unit Fire Sprinkler Systems as it relates to residential fire sprinkler systems. All brand new home construction or homes that are completely destroyed by fire or a natural disaster, such as a tornado, flooding, etc., that must be completely rebuilt, shall be required to adhere to the residential fire sprinkler system requirements contained in sections R313 and P2904.
   (C)   If there are any specific provisions of this code in conflict with the terms of the international residential code (IRC), 2015 edition, the provisions of this code shall control unless there is a contrary indication therein. (Ord. 16-12, 9-27-2016)