§ 17.8.120 MINIMUM ACCESS REQUIREMENTS FOR RESIDENTIAL USES.
   A.   Direct to arterial from a residential established after the effective date of this Code is prohibited. The may permit direct to an arterial for of approved prior to the effective date of this Code, and for multi- residential if the is designed to local residential standards.
   B.    and shall be required to have one , fully improved with hard surface pavement, with a minimum width of ten feet.
   C.   Residential access drives and service drives for multi-   shall be fully improved with hard surface pavement with a minimum width of:
      1.   Sixteen feet when accommodating one-way traffic; or
      2.   Twenty-four feet when accommodating two-way traffic.
   In no case shall the design of said service drive or drives require or facilitate the backward movement or other maneuvering of a vehicle within a .
   D.   Private residential drives shall be provided and maintained in accordance with the provisions of the Uniform Fire Code.
   E.   Dead-end drives in excess of 150 feet shall be provided with approved provisions for the turning around of fire apparatus by one of the following:
      1.   A circular, paved surface having a minimum turn radius measured from center point to outside edge of 35 feet;
      2.   A hammerhead, paved surface with each leg of the hammerhead having a minimum depth of 40 feet and a minimum width of 20 feet; or
      3.   The maximum cross of a required turnaround is 5%.
   F.    grades shall not exceed a maximum of 20%.