§ 152.37 STORM SEWERS.
   (A)   Storm sewers shall be designed and constructed in accordance with applicable portions of the latest “Standard Specifications for Water and Sewer Main Construction in Illinois,” as amended or revised and “Standard Specifications for Road and Bridge Construction.” The storm sewers shall be approved by the City Engineer.
   (B)   Storm sewer inlets shall be Neenah R-3067 or an approved equal.
   (C)   Storm sewer manhole casting shall be of the non-rocking type.
   (D)   Adequate provision shall be made in the subdivision for storm or flood water run- off channels, basins or sewers.
(Ord. 567, passed 10-15-90)