(A) The occupant load factor for purposes of establishing exit requirements from live/work units shall not exceed 300 square feet per person. If the unit is 3,000 square feet or more in area, at least two exits are required. The location of each live/work unit in a multi-unit structure in an LW, Live Work Combining Zone (refer to planning codes) shall be marked by a plaque, diagram or other device visible to emergency personnel from the exterior of the structure containing the unit(s). The location of the plaque, et al, shall be approved by the Fire Marshal.
(B) Emergency egress shall be provided from the sleeping area of the live/work unit as per Section 3104.
(C) Exiting from other occupancies and from the building shall be as required by the Uniform Building Code.
(Ord. 595-C.S., passed 8-15-95; Am. Ord. 608-C.S., passed 6-18-96) Penalty, see § 150.999