921.15 CONNECTIONS TO PUBLIC SEWERS.
   The connection of the building sewer into the public sewer shall be at the adjacent street or right-of-way easement. Connection at the property line shall be made with a clean-out wye at the owner's expense. Such connection shall be made by cutting a neat hole into the public sewer to receive the building sewer, with entry in the downstream direction at an angle of approximately forty-five degrees. A forty-five degree ell may be used to make such connections, with the spigot end cut so as not to extend past the inner surface of the public sewer. The invert of the building sewer at the point of connection shall be at the same or at a higher elevation than the invert of the public sewer. A smooth, neat joint shall be made, and the connection shall be made secure and watertight by encasement in concrete. Special fittings may be used for the connection only when approved by the Service Director.
   The actual tapping of a connection into the sanitary sewer and the connection at the building shall be performed only in the presence of an inspector.