(a) Storm sewers may be located in the center of the right of way or at the edge of the cartway or curb.
(b) Storm drains shall have a minimum diameter of fifteen inches and a minimum grade of one-half percent (0.50%).
(c) Manholes shall be spaced three hundred feet or less for pipes twenty-four inches and under; not more than four hundred fifty feet for pipes twenty-four inches and larger. When approved by the City Engineer, inlets may be substituted for manholes.
(d) Bridges and culverts shall be designed to support the expected loads, to carry expected flows, and be constructed the full width of the right of way, where deemed necessary by the Planning Commission.
(e) Drainage plans shall be submitted for approval with preliminary application.
(f) Inspection of storm drainage shall be made by the City Engineer.
(Ord. 208. Passed 6-7-61.)